SIGLENT
SPD3000X QuickStart 31
6. CURRent
Command format
[{CH1|CH2}:]CURRent <current>
Description
Set current value of the selected channel
Example
CH1:CURRent 0.5
Command format
[{CH1|CH2}:]CURRent?
Description
Query the current value of the selected channel.
Example
CH1: CURRent?
Typical Return
0.500
7. VOLTage
Command format
[{CH1|CH2}:]VOLTage <voltage>
Description
Set voltage value of the selected channel
Example
CH1: VOLTage 25
Command format
[{CH1|CH2}:]VOLTage?
Description
Query the voltage value of the selected channel.
Example
CH1: VOLTage?
Typical Return
25.000