APOLLO User Manual Page 13
delay, alogn with the LED “ΒΥPASS”.
Example: [USER CODE] [BYPASS][01][03][08][12] & [ENTER].
NOTES:
Arming with bypassed zones can only be carried out by users whose
codes have the permission for it. If you use a code that doesn’t have
the right access level, the system will not arm and you will have to
repeat the procedure from the beginning, using the right code. In this
case, the LED “ARM” will not change status and the keypad buzzer
will sound continuously indicating error.
If a zone you wish to bypass does not belong to the partition that you
arm, the system will not arm and you will have to repeat the
procedure from the beginning, without bypassing the specific zone.In
this case, the LED “ARM” will not change status and the keypad
buzzer will sound continuously indicating error.
If any zone is unbalanced and you arm the system without bypassing
them, the control panel will (regarding to the programming the
installer has done) act as follows:
1. The system will not arm.
2. The system will arm and at the end of exit delay will automatically
bypass all unbalanced zones. In this case the siren will sound 3
times indicating you had armed the system with bypassed zones.
3. The system will arm and at the end of exit delay will automatically
bypass all unbalanced zones. The siren will stay silent.
4. The system will arm and at the end of exit delay will automatically
bypass all unbalanced zones, without any indication. If during the
arming cycle the zones are balanced, they will be automatically
armed, and sound an alarm if triggered (FORCED ARM).
To bypass certain zones, which are common in both partitions, you
must bypass them at each partition separately.
The zones that will be bypassed, with the above mentioned
method, will automatically return to normal operation mode,
when the system disarms.