Enter [USER CODE] and press [ENTER]. The panel will start the
exit delay countdown. If no delay zone “opens” during the exit delay,
the system will automatically HOME arm, bypassing all interior zones.
In this case, the entry delay will be active. If any of the users is out
of the premices, can enter from a delay zone and disarm the system,
during the entry delay, by using his code. This method can not be used
in the following cases:
i. When the zone DELAY is bypassed
ii. When the system is armed via a key-switch zone which has no exit
delay
3. In case you wish to HOME arm the system and also bypass some other
zones, enter [USER CODE], press [BYPASS] enter [ZONES TO BE
BYPASS] and then press [ΗΟME] & [ENTER].
If you had HOME armed the system, and wish to exit the
premices, without disarming the system, press the key [BYPASS]. The
exit delay will start countdown, and you may leave the area. After the
end of the delay time the system will be in HOME ARM status.
If you use this last method to exit your premices by pressing the key
[BYPASS], the entry delay will be active, regardless the method you used
to HOME arm the system.
CHANGING ARMING STATUS: If you had HOME armed the
system, you may activate or cancel the entry delay by pressing the key
[ΗΟΜΕ]. When the LED “ARM” is blinking the entry delay is active,
while when it is off the entry delay is de-activated.
DISARMING: To disarm the system, if you had armed it using
HOME arming, enter [USER CODE] and press [ENTER]. As a
confirmation the LED “ARM” will change status.
CANCEL AN ALARM
To cancel an alarm enter [USER CODE] and press [ENTER]. The
sirens of the system will be silenced, and the digital communicator will
report to the Centarl Station.