Instruction, use and maintenance manual Pag. 18/39
BMR 20-20H-30 Planetary Mixer
10.2. Control panel
METHOD OF USE
First of all, make sure the emergency button has been released. The planetary mixer can work in continuous mode
or with a digital timer. If the bowl and the grid are properly closed, steady blue lights will appear on the display. If
the lights are flashing, check bowl positioning again or rotate the protection grid until the lights go back to steady on
the display.
If you wish to operate manually with the continuous work cycle, press the green "START" key to start the work
cycle. During this stage, the display will show the lights moving horizontally. Pressing the "STOP" key stops the
machine and the lights go back to being 4 steady.
DIGITAL TIMER MODE:
If you wish to use the digital timer supplied on the board, press the "MODE" key once. The last set time will appear
on the display, expressed in minutes and seconds. If the time shown is the correct one, press "START" and the
work cycle begins. During the work stage, you will notice a countdown, at the end of which the planetary mixer will
stop automatically.
Programming the timer:
If you wish to set a different time than the one shown on the display, hold down the "MODE" key for a few seconds.
The current time begins flashing on the minute digits. Pressing the "+" and "-" keys, you can increase or decrease
the digits until you reach the desired time. Pressing the "MODE" key once again makes the seconds digits flash.