EasyManua.ls Logo

Signode BXT2-19 - Trouble Shooting

Signode BXT2-19
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
10.13
SIGNODE BXT2-19
E +
E11
E20
E22
E23
E37
7.4 TROUBLE SHOOTING
If a malfunction occurs, the digital display blinks and
displays error “E” followed by the error number.
FAULT / AVERÍA / PANNE
FAULT:
Rocker lever was operated before the cooling-down
period had elapsed.
ACTION:
Operate the rocker lever only when the cooling-down
period has elapsed.
FAULT:
The battery used is not the right type.
CAUSE:
Wrong battery.
ACTION:
Use the correct battery.
Restart by removing/replacing the battery.
FAULT:
Battery too hot.
CAUSE:
– Batterytemperatureabove60°C.
ACTION:
Let the battery cool down.
Replace the battery.
FAULT:
Motor overload protection.
CAUSE:
The motor was overloaded.
ACTION:
Let the motor cool down.
FAULT:
Battery discharged.
CAUSE:
The lowest charge limit of the battery has been
reached.
ACTION:
Charge/replace the battery.
FAULT:
Rocker lever is blocked.
CAUSE:
Tool blocks when welding.
ACTION:
Refer to chapter 6.3 or by Service Centre.
For other error numbers not described here,
please contact the Service Centre.
+