Page #21 background imageLoading...
Page #21 background image
SIKA TD 32500 Operating Manual
5.2.6 Programming frequency divider
You can only carry out this configuration, if TD 32500 is equipped with a
frequency divider output.
With this programming you determine the factor by which the input pulse
rate generated by the flow sensor is divided in order to allow output at a
smaller pulse rate.
Note: If the built-in flow sensor provides for example a pulse rate of
855 pulses/liter (printed on type plate) and a factor "6" is
programmed, a pulse rate of 142,5 pulses/liter is quoted at the outlet.
P
roceed as follows:
Switch over to configuration menu.
Press the
key until the message
„SET PULSE DIVIDE NO“ appears.
Switch with the key to „YES“ and confirm with the
key.
The message appears „VALUE OK ?“ together with the last entered
fa
ctor.
Switch with the key to „CHANGE VALUE ?“ and confirm with the
key.
A cursor appears. Set with the key the respective digit of the new
factor and confirm it with the
key.
5.2.7 Quit configuration menu
The message „QUIT CONFIG NO“ appears.
Switch with the key to „YES“ and confirm with the
key.
The configuration menu is quit. TD 32500 switches back to
m
easurement operation.
If you confirm with "NO", the system returns to the beginning of the
configuration menu.
Note: By simultaneous pressing the keys and
at any position in
the configuration menu, the instrument switches to the menu item
"Quit configuration menu".