    Stephanie CainAug 14, 2025
    Why Sima DEL-32 doesn't have enough power to cut or bend?
    • M
      morgancatherineAug 15, 2025
      If your Sima Industrial Equipment lacks power for cutting or bending, several factors could be responsible. Check for loose or damaged belts and tighten or replace them as needed. Inspect the blades for damage; replace them or try using the other cutting side. Also, verify that the motor is receiving the correct current; if not, schedule a technical service check for the engine.
  • D
    Dawn GarciaAug 18, 2025
    What to do if the pilot light is on but the Sima DEL-32 Industrial Equipment doesn't work?
    • V
      Vanessa WellsAug 18, 2025
      If the pilot light is on but your Sima Industrial Equipment isn't working, there are a few things to check. First, ensure that the machine is correctly connected and that all phases are complete. Also, check the fuse in the machine's electrical box. Make sure the emergency stop button is not depressed. Finally, verify that all security features are correctly in place, including doors, emergency stop buttons, and the plastic table top guard.
  • M
    Mr. Richard BowersAug 21, 2025
    Why the bending plate doesn’t stop immediately when the pedal is released on my Sima DEL-32 Industrial Equipment?
    • L
      Linda MichaelAug 21, 2025
      If your Sima Industrial Equipment's bending plate doesn't stop immediately when the pedal is released, it could be due to a worn motor brake. Inspect the motor brake and tighten the springs, ensuring a uniform gap between the disc and the plate of .3 to .4mm. If the motor brake is not operational, consider replacing it.
  • M
    Morgan JohnsonAug 25, 2025
    What to do if Sima DEL-32 doesn’t have enough current and the pilot light doesn’t come on?
    • S
      Stacy AndersonAug 25, 2025
      If your Sima Industrial Equipment isn't receiving enough current and the pilot light doesn't come on, start by checking the site junction box to ensure electricity is being produced. Verify the current from the mains. Check the fuse on the junction box and re-arm it if necessary. Finally, inspect the cables and replace them if they are in bad condition.
  • M
    Madison RobinsonAug 28, 2025
    Why the bending plate doesn´t return to its original position after the bend is complete on my Sima Industrial Equipment?
    • Y
      Yvette NelsonAug 28, 2025
      If your Sima Industrial Equipment's bending plate doesn’t return to its original position after bending, the inductive sensor might be defective. Check the sensor (1 open, 0 closed) and replace it if damaged.
  • O
    okingAug 31, 2025
    How to fix oil leak from the gearbox of Sima DEL-32?
    • A
      armstrongjoseAug 31, 2025
      If your Sima Industrial Equipment loses oil through the gearbox, the rubber washer might be deteriorated. Replace the rubber washer to resolve this issue.
  • L
    Leroy JonesSep 3, 2025
    What to do if the plate doesn't stop at the original position after bending with Sima DEL-32?
    • D
      denise76Sep 4, 2025
      If, after bending, the plate on your Sima Industrial Equipment doesn't stop at the original position, the inductive sensor may be defective. Check the sensor (1 open, 0 closed), and replace it if damaged.
  • H
    Heather VaughnSep 7, 2025
    Why Sima DEL-32 Industrial Equipment doesn’t have enough power despite correct 230v or 400v connection?
    • E
      Eric PeckSep 7, 2025
      If your Sima Industrial Equipment doesn't have enough power even with the correct 230v or 400v connection, the electricity supply might be unstable. Verify that the voltage is not inferior to 230v or 400v, as the machine won't work correctly under that voltage. Using a tension stabilizer is recommended.
  • O
    Omar KleinSep 10, 2025
    What causes a strange noise from within the gearbox of Sima Industrial Equipment?
    • M
      Matthew MclaughlinSep 10, 2025
      If you notice a strange noise coming from the gearbox of your Sima Industrial Equipment, it could be due to the deterioration of some internal components. Dismantle the gearbox and inspect the bearings and grooves, replacing any damaged elements.

Summary

General Description of the Machine

Parts of the Machine

Starting-Up and Using the Machine

Plugging the Machine to the Electricity

Electrical connection requirements, cable specifications, and safety notes.

Connecting to Electricity Source

Step-by-step guide to safely connect the machine to the power supply.

Electrical Schemes

Overview of the machine's electrical diagrams and wiring schematics.

Bending with Support Device or Mandrels

Making a Bend

Making a Cut

Maintenance, Inspection and Control

Del Tronic and Combi Tronic Models

Automatic Mode Operation

Operating the machine via the mobile app in automatic mode.

Trouble Shooting

Safety Recommendations

Sima DEL-32 Specifications

General IconGeneral
BrandSima
ModelDEL-32
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals