19-6432-M-01 Rev 4 2
1.1 Point of Use Ionizing Blower Model
6432e
The Point of Use Ionizing Blower Model 6432e controls static
discharge in areas where static build-up can cause contamination,
ESD, material-handling problems, or microprocessor lock-up. The
internal emitter points are electrostatically shielded to eliminate
field-induced charging. Steady-state DC ion emission provides fast
discharge with low airflow.
The Model 6432e features a red alarm indicator LED on the front of
the Blower. See 2.8 Alarms section for a discussion of the alarm
function. The eight-pin terminal strip provides a 4-20 mA current
loop and relay output connection to your facility monitoring system
(FMS) in addition to the 24 VDC input connection.
Figure 1. Front of the Model 6432e Blower