1.3 Performance
The Blower will reduce a static charge of ±1,000V down to ±100V in
approximately 4 seconds at a distance of 1 ft. (30.48 cm) when
powered with 24 VAC. See the table below for typical discharge
times as determined by distance. Distance is measured from the
front center of the Blower. Ionization balance is better than ±20V at
1 ft. (30.48 cm).
Table 1. Distance/Discharge Time when Powered with 24 VAC
Testing was performed with a charged plate monitor in accordance
with ionization standard ANSI/ESD STM3.1-2006 of the ESD
Association.
Distance Discharge Time
1 foot (30.48 cm) 4 seconds
2 feet (61 cm) 7 seconds
3 feet (91.44 cm) 11 seconds
4 feet (122 cm) 17 seconds
Note:
The performance of the Model 6432 will be reduced slightly
when the unit is powered with 24 VDC.