SIM7500_SIM7600_SIM7800 Series_FTPS_AT Command Manual 14 / 29
+CFTPSGET: DATA,<len>
+CFTPSGET: DATA, <len>
+CFTPSGET: 0
b) if <using_cache> is 1 and get file successfully:
OK
+CFTPS: RECV EVENT
AT+CFTPSCACHERD?//you can use this command to
//check the size of the received
//data
+CFTPSCACHERD: 102400
OK
//output cached data now:
AT+CFTPSCACHERD
+CFTPSGET: DATA,<len>
…...
OK
......
+CFTPSGET: 0
c)if failed:
OK
+CFTPSGET:<errcode>
d)if parameter format or any other errors:
ERROR
Defined Values
<filepath>
The remote file path. When the file path doesn’t contain ”/”
this command transfer file from the current remote FTPS
directory. If the file path contains non-ASCII characters, the file
path parameter should contain a prefix of {non-ascii}.String
type, maximum length is 256.
<rest_size>
The value for FTP “REST” command which is used for broken
transfer when transferring failed last time. Numeric type, the
range is from 0 to 2147483647
<using_cache>
Numeric, rang is 0-1
0–Do not use cache, module will output the items data to serial
port when list successfully.

Other manuals for SimCom SIM7800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7800 Series and is the answer not in the manual?

SimCom SIM7800 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7800 Series
CategoryControl Unit
LanguageEnglish

Related product manuals