13
MODEL: VE 26 / 039-8119-2
8. Cleaning and Maintenance
8.1 Connections
The connections on the pressure washer’s hoses, gun, and
spray wand should be cleaned and lubricated with non-water
soluble grease regularly.
8.3 Water Filter Screen
The pressure washer is equipped with a water inlet screen
to protect the pump. If the screen is not kept clean, the flow
of water to the pressure washer will be restricted, and the
pump may become damaged.
To clean the water inlet screen:
Remove the filter screen from inside the inlet adaptor
(the inlet adaptor comes pre-assembled to the machine).
Rinse the screen until it is free of debris and obstructions.
Place the screen back to prevent foreign particles from
entering the pump.
9. Technical Specifications
Peak pressure: 1800 PSI
Rated pressure: 1000 PSI
Power source requirement: 120 V / 60 Hz
Cord: 23’ (7m), 16 AWG
High-pressure hose: 20’ (6 m)
MAX flow: 1.8 U.S. GPM (6.9 LPM)
Current drawn: 13 A
Inlet water: Cold tap water
Cleaning and Maintenance
8.2 Cleaning the Nozzles
Clogging of the nozzle causes the pump pressure to be too
high, making it necessary to clean the nozzle immediately.
You can clean the nozzle by carefully inserting the cleaning
needle or a thin, sharp instrument (i.e., paper clip) into the
tip to clean out any deposits.