User Manual
For in vitro diagnostic use only
Safe-Accu
Blood Glucose Meter
Blood Glucose Monitoring System
Version No.:181025-1
Shanghai International Holding Corp. GmbH (Europe)
Eiffestraße 80, 20537 Hamburg, Germany.
Tel: +49-40-2513175 Fax: +49-40-255726
E-mail: shholding@hotmail.com
No. 265, Guyuan Road, Hi-Tech Zone, Changsha,
Hunan Province, 410205,People’s Republic of China
TEL:+86-731-89935581/89935582
Email:info@sinocare.com
Website:www.sinocare.com

Questions and Answers

  • J
    Julia JohnsonAug 14, 2025
    What to do if Sinocare Safe-Accu doesn’t begin test after applying a blood sample?
    • W
      wagnermichaelAug 14, 2025
      If the meter doesn’t start after applying blood, consider these possibilities: * There might not be enough blood sample. In this case, repeat the test using a new test strip and ensure you provide an adequate sample. * The blood sample may have been applied to the wrong area of the test strip. Repeat the test with a new strip, making sure the blood is drawn into the correct area. * The test strip may be used. Repeat the test with a new test strip. * The test strip was exposed to air too long after opening. Finish the test immediately after taking a test strip from a vial or package.
  • E
    Edward HarrisAug 17, 2025
    What to do if Sinocare Blood Glucose Meter shows result above measurement limit?
    • S
      Steven HuangAug 17, 2025
      If your Sinocare Blood Glucose Meter displays a result above the measurement limit, which is higher than 600 mg/dL or higher than 33.3 mmol/L, use a new test strip and test again. If the meter continues to display “HI”, it is important to immediately contact a healthcare professional for assistance.
  • C
    Christopher BrownAug 21, 2025
    What to do if Sinocare Safe-Accu Blood Glucose Meter shows result below measurement limit?
    • C
      Catherine HunterAug 21, 2025
      If your Sinocare Blood Glucose Meter shows a result below the measurement limit (less than 20 mg/dL or less than 1.1 mmol/L), use a new test strip to test again. If the meter still displays “LO”, call your healthcare professional immediately.
  • M
    martinginaAug 25, 2025
    How to fix low battery power on Sinocare Blood Glucose Meter?
    • S
      Sean PaulAug 25, 2025
      If your Sinocare Blood Glucose Meter indicates low battery power, replace the batteries immediately.
  • J
    John Torres MDAug 27, 2025
    Why Sinocare Blood Glucose Meter shows test method error?
    • S
      Suzanne DeanAug 27, 2025
      The Sinocare Blood Glucose Meter shows a test method error because the test strip was inserted into the meter after the sample was applied to the strip. To correct this, insert the test strip into the meter before applying the sample to the strip.
  • J
    jacksonbrandonAug 30, 2025
    What to do if I used test strip with Sinocare Blood Glucose Meter?
    • A
      Ashley HubbardAug 30, 2025
      If you've used a test strip with your Sinocare Blood Glucose Meter, you need to use a new test strip to test again.
  • B
    brandi23Sep 3, 2025
    What to do if I have expired test strip or damped test strip for Sinocare Safe-Accu?
    • D
      Daniel HollandSep 3, 2025
      If you have an expired or damped test strip for your Sinocare Blood Glucose Meter, use a new test strip to test again.
  • R
    Ronald FosterSep 6, 2025
    What happens if test strip exposed to air more than 3 minutes for Sinocare Safe-Accu Blood Glucose Meter?
    • D
      Daniel JonesSep 6, 2025
      If the test strip has been exposed to air for more than 3 minutes when using the Sinocare Blood Glucose Meter, you should use a new test strip to test again.
  • A
    Ann WilliamsSep 9, 2025
    How to fix incorrectly installed battery in Sinocare Safe-Accu Blood Glucose Meter?
    • D
      Dawn MosleySep 10, 2025
      To fix an incorrectly installed battery in your Sinocare Blood Glucose Meter, check that the battery is correctly installed with the right position of sign “+” and “-.”

Sinocare Safe-Accu Specifications

General IconGeneral
Measurement Range20-600 mg/dL
Sample TypeCapillary whole blood
Test Time10 seconds
Power Source2 x AAA batteries
Memory Capacity200 test results
Operating Conditions10-40°C, 10-90% RH
Sample Volume0.6 μL
Automatic ShutoffYes, after 3 minutes
Weight50 g (without batteries)

Related product manuals