Output #X is shorted.
A short circuit has been detected on an
output pin. Remove the short circuit, and
clear the error to resume use of this pin.
Turn Run switch to Hold to continue.
On systems with a
RUN-HOLD
switch, the
switch must be in the
HOLD
position before
operations can begin after system
power-on. This prevents inadvertently
engaging material at power-on.
Turn off Start switch to continue.
On systems with a
START-STOP
switch, the
switch must be in the
STOP
position before
operations can begin after system
power-on. This prevents inadvertently
engaging material at power-on.
Flash image mismatch: update image via
USB.
Images and audio files for the program do
not match the main program installed on
the system.
Insert a USB drive with the correct
update file.
Contact Skip-Line for support.
Flash memory unreadable.
The flash memory that contains graphics,
audio files, and logged counter channel
records is not communicating.
Contact Skip-Line for support.
Duplicate switch detected. Fix and cycle
power.
A switch with the same function is
connected via the CAN expansion port, or
devices with incompatible programs are
both on the same system.
Remove other devices from the CAN
bus.
A full system power cycle is required
to clear this error.
Contact Skip-Line for support.
No communication with Core
Skipper.
The SC-12 master boxes must be able to
communicate with the Core Skipper device
in order to operate, since the Core Skipper
is the central computer for the system.
SC-12 Road Marking Control System - Installation and Operation Manual
60