8.9 vReset to default
Open the housing.
Lever the left plastic plug with terminals a+/b-/E+/E- out of its holder
using a screwdriver.
+ v
Keep hold of the programming key at the back of the device while re-
connecting the BUS by plugging the terminals E-/E+/b-/a (from left to
right) onto the four contacts on the right.
Keep hold of the programming key until you hear a signal tone, show-
ing that the reset has been successful.
All settings are now back to default, all call addresses and internal call
addresses are deleted.
KLICK
After that remove terminals a+/b-/E+/E- from the contacts and remount