SJ9233 RT, SJ9243 RT, SJ9253 RT, SJ9664 RT 221491AFA
Optional equipment Section 3 – Familiarization
IMPORTANT
If the set time of the access control unit expires,
enter the PIN code or tap the Smart ID card again.
If there is a failure of the access control activation,
speak to the MEWP owner.
IMPORTANT
The access control unit will not operate if these
power connections are not ON in the set time, or if
the operator disconnects them:
The main power disconnect switch
The emergency-stop button on the base
control console
The off/base/platform key switch.
IMPORTANT
To start the access control unit, enter the PIN
code or tap the Smart ID card. These power
connections must be in the ON position in the set
time:
The main power disconnect switch
The emergency-stop button on the base
control console
The off/base/platform key switch.
Function Tests
Do the function tests as specified in Section 4.3.
When you do the function tests, make sure that the
green light on the keypad is ON. This light confirms
that the access control unit is in operation. Do the
function tests for these power connections in the set
time:
The main power disconnect switch
The emergency-stop button on the base control
console
The off/base/platform key switch.
3.6-3 Cold Weather Start Kit Operation
Plug heaters in a minimum of 4 hours before
operation.
WARNING
Do not leave heaters on for more than 12 hours
consecutively.
WARNING
Do no use heaters if temperature is above freezing.
WARNING
Make sure hydraulic oil level is visible in the sight
gauge.
WARNING
Make sure the electrical circuit can handle the
combined current draw from the hydraulic tank
heater, battery blanket, and block heater.
FAMILIARIZATION