EasyManua.ls Logo

Skyjack SJ9664 RT - 10 Do a Test of the Drive Function; 11 Do a Test of the Anti-Tiedown Function

Skyjack SJ9664 RT
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
SJ9233 RT, SJ9243 RT, SJ9253 RT, SJ9664 RT 221491AFA
Function tests Section 4 – Inspections Before Operation
4.3-10 Do a test of the drive function
1. Make sure the path of intended motion is clear.
2. Move the lift/off/drive switch
3
to the drive
position
3a
.
3. Squeeze and hold the function-enable switch
4
.
4. Slowly push the controller handle
5
until the
MEWP starts to move. Then, release the handle,
so that it goes back to the center position.
Result: The MEWP moves in the forward
direction and then stops.
5. Slowly pull the controller handle
5
until the
MEWP starts to move. Then, release the handle,
so that it goes back to the center position.
Result: The MEWP moves in the opposite
direction and then stops.
4.3-11 Do a test of the anti-tiedown
function
1. Make sure the path of intended motion is clear.
2. Move the lift/off/drive switch
3
to the drive
position
3a
.
3. Squeeze and hold the function-enable switch
4
for 7 seconds.
4. Slowly push the controller handle
5
to move
the MEWP in the forward direction.
Result: The MEWP does not move in the
forward direction.
TM
4
3a
5
3
3b

Table of Contents