51
SJ9233 RT, SJ9243 RT, SJ9253 RT, SJ9664 RT 221491AFA
Function tests Section 4 – Inspections Before Operation
4.3-10 Do a test of the drive function
1. Make sure the path of intended motion is clear.
2. Move the lift/off/drive switch
3
to the drive
position
3a
.
3. Squeeze and hold the function-enable switch
4
.
4. Slowly push the controller handle
5
until the
MEWP starts to move. Then, release the handle,
so that it goes back to the center position.
▪
Result: The MEWP moves in the forward
direction and then stops.
5. Slowly pull the controller handle
5
until the
MEWP starts to move. Then, release the handle,
so that it goes back to the center position.
▪
Result: The MEWP moves in the opposite
direction and then stops.
4.3-11 Do a test of the anti-tiedown
function
1. Make sure the path of intended motion is clear.
2. Move the lift/off/drive switch
3
to the drive
position
3a
.
3. Squeeze and hold the function-enable switch
4
for 7 seconds.
4. Slowly push the controller handle
5
to move
the MEWP in the forward direction.
▪
Result: The MEWP does not move in the
forward direction.
TM
4
3a
5
3
3b