Ref : 26702 12 07/01/15
CELL Cell input management option : OUI, NON, LIMI
(YES, NO, LIMI)
The cell must be a normally closed (NF) and must
be connected to ARIANE
The cell is automatically viewed during learning and filled
in. The CELL parameter allows eliminating it, if
necessary.
With the LIMI option : The cell is inhibited as the door is
reset after a mains power failure (230 VAC).
TYPE Door type selection :
BATT : Operator installed in front of a swinging door
FI : Operator with fixed blade
MOBI : Operator with mobile skate
Warning ! In case of a door type change, a new
learning procedure must be performed (CMD1).
RMF2 Choice of multifunction output relays use
BUZZ : a buzzer sounds when the door moves
RMF1 Learning, reset, nudging movements or fail stop.
BUTE : intermediate end stop control when two open
travel ranges are to be used.
CAME : driving of an electro-cam for swinging door type
BATT or MOBI, or for shutter door type FI.
VENT : an electromagnetic suction disc is driven to
keep the door locked if the close order is maintained.
Pini Allows loading the pre-programmed or saved adjustment
values after the Asynchronous or Brushless motor
type (MOTR) is selected.
INIT allows restoring the last saved parameter setting.
SAVE allows saving the current adjustment.
In01, In02, In03 etc. … allows loading the factory
parameter range tables corresponding to the various
door types.