Ref : 26702 11 07/01/15
CONFIGURATION PARAMETERS DETAILS
MSTF
Hold closed under voltage OUI, NON or DEPL (YES,
NO, or DISPL)
DEPL = Moving : The motor is held under voltage if the
closing input is activated. Generally, non (no) for
automatic doors and oui (yes) for swinging doors.
If there is a mechanical holding hook to keep the
door in closed position, select NON (NO).
MSTO Hold opened under voltage OUI, NON (YES, NO).
Generally, oui (yes) for automatic doors and non
(no) for swinging doors.
In case a mechanical retaining hook is present to
keep the door in the open position, select NON (NO).
MODE Behaviour choice in case door blocking in closing
ESCL : Slave mode. Door not opened, but the Obstacle
relay activated. The controller time out reversal must
be set to 0.
MA-1: Master mode 1. Door completely opened with
time out in case blocking
or cell detection with the Obstacle relay activated.
MA-2: Master mode 2. Door opens as long as the cell
signal lasts in case of cell detection. Otherwise, door
immediately closed
.
The Obstacle relay is activated in case of a shock, or in
case of complete reopening driven by the cell.
CHOC The OBSTACLE relay operating direction : NO, NF
(Normally Open, Normally Closed)
FDC Operating direction of the relays FdC-O (OLS)/FdC-F
(CLS):
NO, NF (Normally Open, Normally Closed)
SMOT Motor direction software reversal : DIR or INV
VITR Glazed door option : OUI, NON (YES, NO) allows
preventing finger jamming as door opens.