EasyManua.ls Logo

SMA SUNNY BOY 1300TL - 6 Electrical Connection; Safety During Electrical Connection; Overview of the Connection Area; View from below

SMA SUNNY BOY 1300TL
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Electrical Connection SMA Solar Technology AG
24 SB13_21TL-IA-en-65 Installation Manual
6 Electrical Connection
6.1 Safety during Electrical Connection
Electric Shock
When exposed to sunlight, the PV array generates dangerous DC voltage which is present in the
DC conductors and the live components of the inverter. Touching the DC conductors or the live
components can lead to lethal electric shocks.
Do not touch the DC conductors.
Do not touch any live components of the inverter.
Prior to performing any work on the inverter, disconnect it from all voltage sources as described
in this document (see Section 9).
Electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter through electrostatic
discharge.
Earth yourself before touching any components.
6.2 Overview of the Connection Area
6.2.1 View from Below
Figure8: Connection areas and enclosure openings at the bottom of the SB 2100TL
Item Description
A Positive DC connectors for positive DC cables
(in SB 1300TL-10 and SB 1600TL-10 there is only 1 positive connector)
BSocket for the ESS*
*optional
C Negative DC connectors for negative DC cables
(in SB 1300TL-10 and SB 1600TL-10 there is only 1 negative connector)
D Enclosure openings with filler plugs for data cables
E Female connector for AC coupling socket

Table of Contents

Other manuals for SMA SUNNY BOY 1300TL

Related product manuals