SMA Solar Technology AG 12 Technical Data
Installation Manual SB13_21TL-IA-en-65 63
Features
Fault Indicator Relay
Electronic Solar Switch*
DC connection SUNCLIX DC connector
AC Connection AC connector
Display LC text display
Bluetooth
®
Wireless Technology optional
RS485, galvanically isolated optional
Speedwire with Webconnect function optional
Maximum AC switching voltage 240 V
Maximum DC switching voltage 30 V
Maximum AC switching current 1.0 A
Maximum DC switching current 1.0 A
Minimum electrical endurance when the
maximum switching voltage and maximum
switching current are complied with*
* Corresponds to 20 years at 12 switching operations per day
1,000,000 switching cycles
*optional
Electrical endurance in the event of a short
circuit, at nominal current of 35 A
at least 50 switching operations
Maximum switching current 35 A
Maximum switching voltage 800 V
Maximum PV power 11 kW
Degree of protection when plugged in IP65
Degree of protection when unplugged IP21
Fuse for Electronic Solar Switch F200, 600 V/4 A, fast
(soldered, not replaceable)