SMA America, LLC Electrical connection
Installation Guide SB30-40US-IUS103030 45
6.7 DC wiring
DANGER
High voltage is present in PV modules exposed to light.
Death due to electric shock when touching a DC conductor.
During installation, cover the PV modules with opaque material.
DANGER
High voltage is present inside the DC cables.
Death or serious injury will result when damaging a DC cable or touching a DC conductor.
You have to connect the DC cables from the PV array to the Sunny Boy in the order
described in this manual.
NOTICE
Damage to the inverter due to overvoltage.
Verify that the DC current of your installation does not exceed the maximum values
specified on the type rating label.
NOTICE
Irreversible damage to the inverter due to DC-input voltage that exceeds the maximum
DC‑input-voltage range.
Verify the polarity and the open-circuit voltage from the PV strings, before connecting
the DC wires to the inverter.
Check both the polarity and the open-circuit voltage from the PV strings.
Configure the DC-input-voltage range correctly before connecting the DC-input wires
from the PV array to the inverter.
Use the free design programs "Solar Design Tools" at www.SMA-America.com to
determine the correct string configuration.