SMA America, LLC Technical specifications
Installation Guide SB30-40US-IUS103030 89
11.3 Sunny Boy 3000-US
PV generator connection
Grid connection
Mechanical data
Peak Power Tracking Voltage at 208V nominal 180V…400V
Peak Power Tracking Voltage at 240V nominal 200V…400V
Range of Input Operating Voltage 200V … 500V
Maximum Array Input Power 3,750W
Maximum DC Power 3,250W
PV Start Voltage 230V
Maximum DC Input Current 17A
Maximum Input Short Circuit Current 24A
DC Voltage Ripple < 10%
AC Operating Voltage Range at 208V nominal 183V … 229V
AC Operating Voltage Range at 240V nominal 211V …264V
AC Operating Frequency Range 59.3Hz…60.5Hz
AC Frequency Nominal 60Hz
AC Maximum Continous Output Power 3,000W
Current THD < 4%
AC Maximum Continous Output Current at 208V 15A
AC Maximum Continous Output Current at 240V 13A
Maximum Output Fault Current 30A
Maximum Output Overcurrent Protection 30A
Maximun Utility Backfeed Current to PV array 30A AC
Synchronization In-Rush Current 8A
Trip Limit Accuracy ±2%
Trip Time Accuracy ±0.1%
Power Consumption at Night 0.1W
WidthxHeightxDepth 17.80in.x13.83in.x9.30in.
(462mmx351mmx236mm)
Weight 88lbs.(40kg)
Noise Emission 40dB(A)