SMA America, LLC Technical specifications
Installation Guide SB30-40US-IUS103030 93
11.5 Sunny Boy 4000-US
PV generator connection
Grid connection
Mechanical data
Peak Power Tracking Voltage at 208V nominal 220V…480V
Peak Power Tracking Voltage at 240V nominal 250V…480V
Range of Input Operating Voltage 250V … 600V
Maximum Array Input Power 5,000W
Maximum DC Power 4,300W
PV Start Voltage 285V
Maximum DC Input Current 18A
Maximum Input Short Circuit Current 25A
Maximun Utility Backfeed Current to PV array 30A AC
DC Voltage Ripple < 10%
AC Operating Voltage Range at 208V nominal 183V … 229V
AC Operating Voltage Range at 240V nominal 211V …264V
AC Operating Frequency Range 59.3Hz…60.5Hz
AC Frequency Nominal 60Hz
AC Maximum Continous Output Power 4,000W
Current THD < 4%
AC Maximum Continous Output Current at 208V 17A
AC Maximum Continous Output Current at 240V 17A
Maximum Output Fault Current 30A
Maximum Output Overcurrent Protection 30A
Synchronization In-Rush Current 8A
Trip Limit Accuracy ±2%
Trip Time Accuracy ±0.1%
Power Consumption at Night 0.1W
WidthxHeightxDepth 17.80in.x13.83in.x9.30in.
(462mmx351mmx236mm)
Weight 88lbs.(40kg)
Noise Emission 40dB(A)