Parameter Explanation Values Default val-
ues
NetworkSettings_Dns2IpAddr1 Sets the second IPv4 address of the
DNS server for LAN2
0.0.0.0
0.0.0.0
A valid IPv4
address
NetworkSettings_Gateway1 Sets the gateway address for LAN2 0.0.0.0 0.0.0.0
NetworkSettings_IpAddr1 Sets the IPv4 address for LAN2 A valid IPv4
address
172.24.1.51
NetworkSettings_SubnetMask1 Sets the subnet mask for LAN2 255.255.0.0 255.255.0.0
NetworkSettings_DhcpUsage2 Activates DHCP for LAN3. With the
True value, all other settings of the IP
addresses for LAN3 will be ignored.
True False
False
NetworkSettings_DnsIpAddr2 Sets the first IPv4 address of the DNS
server for LAN3
0.0.0.0
A valid IPv4
address
NetworkSettings_Dns2IpAddr2 Sets the second IPv4 address of the
DNS server for LAN3
0.0.0.0
0.0.0.0
A valid IPv4
address
NetworkSettings_Gateway2 Sets the gateway address for LAN3 0.0.0.0 0.0.0.0
NetworkSettings_IpAddr2 Sets the IPv4 address for LAN3 A valid IPv4
address
172.16.1.51
NetworkSettings_SubnetMask2 Sets the subnet mask for LAN3 255.255.0.0 255.255.0.0
NetworkSettings_ModbusPort Sets the Modbus port. Do not use the
following ports: 21 / 23 / 8081 /
30100
502
NetworkSettings_ModbusUsage Activates use of the Modbus protocol True True
False
NetworkSettings_WebserverPort Sets port of the web server. Do not use
the following ports: 21 / 23 / 502 /
8081 / 30100
80