SMA America, LLC Archiving Data on an SD Card
Technical Description SI5048U-TUS121440 99
Firmware Update in a System with one Sunny Island Inverter
Firmware Update in a System with Several Sunny Island Inverters
In a system with several Sunny Island inverters, the firmware is only updated on the master. If the
master detects that a slave has a different firmware version, it transmits its firmware to the slave and
makes sure that all Sunny Island inverters within a system operate with the identical firmware version.
While the master updates the slaves, the devices display, among others, the following messages.. The
display duration of the display messages listed below may vary. Wait until the master displays the
message ”Update finished. Press Enter” and the slaves display the message ”Ready. Wait for
Master.” Do no enter anything while the update is running.
Starting QCG
If you have carried out a firmware update in which the number before the dot in the
firmware version has changed, it is advisable to start QCG and to perform all settings
anew.
During the update, the Sunny Island displays the following
messages.
Display message Message shown by Explanation
Master Update of master starts.
Master Update of master
part1/2.
Master Update of master
part2/2.
Load parameter