SUNNY TRIPOWER
STP50-40-BE-en-15 | Version 1.5ENGLISH
Operating manual
SunnyTripowerCORE1 (STP 50-40)

Table of Contents

Other manuals for SMA SUNNY TRIPOWER CORE1

Questions and Answers:

SMA SUNNY TRIPOWER CORE1 Specifications

General IconGeneral
Max. DC voltage1100 V
Number of MPP trackers6
Max. input current per MPPT26 A
Operating temperature range-25°C to +60°C
TopologyTransformerless
Degree of protectionIP65
Max. apparent AC power50 kVA
AC nominal voltage400 V
THD< 3%
AC grid frequency50 Hz / 60 Hz
Max. input voltage1100 V
Min. input voltage200 V
Number of DC connections per MPPT2
Max. efficiency98.1%
MPPT voltage range200 V - 800 V
AC voltage range320 V to 480 V

Summary

2 Safety

2.1 Intended Use

Describes the product's intended purpose as a transformerless PV inverter and its suitability for indoor/outdoor use.

2.2 IMPORTANT SAFETY INSTRUCTIONS

Contains essential safety information that must be observed at all times when working with the product.

4 Product Overview

5 Mounting

5.1 Requirements for Mounting

Outlines the essential requirements for selecting a safe and suitable mounting location for the inverter.

5.2 Mounting the Inverter

Provides step-by-step instructions and precautions for physically mounting the inverter.

6 Electrical Connection

6.2 AC Connection

Details the requirements and procedure for connecting the inverter's AC side.

6.5 DC Connection

Details the requirements and procedure for connecting the inverter's DC side.

7 Commissioning

7.1 Commissioning Procedure

Outlines the step-by-step procedure for commissioning the inverter and integrating it into a system.

7.2 Commissioning the Inverter

Details the requirements and step-by-step process for commissioning the inverter itself.

8 Operation

8.12 Changing Operating Parameters

Provides the basic procedure for changing various operating parameters to optimize inverter performance.

8.24 Updating the Firmware

Provides methods for updating the inverter's firmware via the user interface or USB.

9 Disconnecting the Inverter from Voltage Sources

11 Troubleshooting

11.2 Event Messages

Lists various event messages, their causes, and corrective measures for diagnosing issues.

11.3 Checking the PV System for Ground Faults

Provides procedures for checking the PV system for ground faults and associated safety precautions.

13 Technical Data

15 Contact