SMARTEYE Netx Ethernet IP Control Unit User Manual Page 33
Filename: netx IP Platform User Manual R0 .doc
In Control
A
M
9.1.5 DIAGNOSTIC – ‘d<cr>’
The diagnostic command displays the last diagnostic message. The output from the ‘d’ command
looks like this:
show % d
Rdr 0 21-JAN-2009 13:10:16 A:0 B:0 C:0 X:0 Y:0
9.1.6 SHOW – ‘s<cr>’
The show command will show the label, diagnostics, and errors as they occur in real time. This
is a toggle command, so typing it again will turn it off. The output from the ‘s’ command looks
like this:
show % s
Rdr 0 04-FEB-2008 19:31:47 Label: 3043
Rdr 0 04-FEB-2008 19:31:54 Diagn: A:0 B:0 C:0 X:0 Y:0
Rdr 0 04-FEB-2008 19:31:58 Label: 2607
Rdr 0 04-FEB-2008 19:32:04 Diagn: A:0 B:0 C:0 X:0 Y:0
Rdr 0 04-FEB-2008 19:32:09 Label: 6616
Rdr 0 04-FEB-2008 19:32:09 Error: 99 Diagnostic attempt aborted
9.1.7 VERSION – ‘v<cr>’
The version command displays the current software revision along with the build date. The
output from the ‘v’ command looks like this:
show % v
SMARTEYE Version 2.5.4 Build Date 24-NOV-2010
BootLoader 1.53
9.1.8 RUNTIME – ‘r<cr>’
The runtime command displays the length of time the Netx unit has been running since the last
boot.
show % r
RunTime DDD:HH:MM:SS - 035:22:33:35
9.1.9 EXIT – ‘exit<cr>’
The exit command shuts down the show process ( if active ) and places the aux port back into OS
console mode.
show % exit

Table of Contents