ALC700 Series Light Tower Set Controller
ALC700 Series Light Tower Set Controller 2018-03-02 Version 1.4 Page 29 of 51
6.3 TRIP AND STOP ALARMS
When the controller detects trip and stop signal, it will send signal to turn off #1#8 lights and
then generator is cooling down and stopped.
Shutdown alarms as following:
NO.
Type
Detection range
Description
1
Over
Current
Always active
When controller detects the current is higher than
the set value, it will send a “trip and stop” signal and
the corresponding alarm information will be
displayed on the LCD.
2
Aux. input
1-4
User-defined
When the controller detects auxiliary input ports 1-4
trip alarms, it will send a “trip and stopalarm signal
and the corresponding alarm information will be
displayed on the LCD. If the input port name is
configured by users as xxx, then “xxx trip and stop
will be displayed on the LCD.
NOTE: The trip and stop alarm types of Aux. input are active only when they are
configured by users.