LED Display
Compact wireless base
No.
LED
name
Function
LED status
Description
Color of
LED
ON/
Flashing
1
LRUN
Data link status
indication
Green ON Communication is normal.
— OFF
Communication is not established or the
US1 (for control) power supply is OFF.
2
LERR
Error status
indication
Red ON A communication error has occurred.
— OFF No communication error
3
PWR
US1 (for control)
power supply
status indication
Green ON The US1 (for control) power supply is ON.
— OFF The US1 (for control) power supply is OFF.
4
MS
Base system
status indication
Green ON
The compact wireless base is operating
normally.
Red Flashing
Restorable error is detected. (LED fl ashes
when one diagnostic information item or
more is detected.)
· US1 (for control) power supply voltage
level is abnormal.
· Number of system inputs/outputs setting
error
· Network setting error
· Abnormal number of remote connections
Red ON Non-restorable error is detected.
— OFF The US1 (for control) power supply is OFF.
5
W-SS
Radio wave
receiving
intensity
Green ON
The received power level of all remotes is 3.
Green
Flashing
(1 Hz)
There are connected remotes with a
received power level of 2.
Green
Flashing
(2 Hz)
There are connected remotes with a
received power level of 1.
Red Flashing
All the remotes that support protocol V.1.0
are not connected.
Orange Flashing
All the remotes that support protocol V.2.0
are not connected.
— OFF The remote module is not registered.
6
W-NS
Wireless
communication
connection
status indication
Green ON All the remote connections are normal.
Green Flashing Some remotes are not connected.
Red Flashing No remotes are connected.
Red ON
No remotes are connected.
(Non-restorable error in wireless
communication)
Red
Green
Alternate
fl ashing
Wireless communication connection is
under construction. (Pairing)
— OFF The remote module is not registered.
7
W-MS
Remote system
status indication
Green ON Wireless remote is normal.
Red Flashing
Restorable error is detected. (LED fl ashes
when one diagnostic information item or
more is detected.)
· US1 (for control/input) power supply
voltage level is abnormal.
· US2 (for output) power supply voltage
level is abnormal.
· Excessive I/O setting inputs/outputs
· Analogue I/O upper set limit exceeded
· Analogue input range upper and lower
limit exceeded
· Error in communication between units
· EX600 I/O unit detects diagnostic
information.
· Valve diagnostic information detected
Red ON Non-restorable error is detected.
— OFF Wireless remote not connected