26
Wireless System
Modular Type
EX600-W Series
U sideD side
12345
Valve stations
1
3
0
2
3
5
7
10
2
4
8
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
Wireless unit
(Base module)
EX600-WEN1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
End plate (D side)
EX600-ED4
2-position single
SY3100-5U1 (3 sets)
2-position double
SY3200-5U1 (2 sets)
D side
U side
Wireless unit (Base module)
EX600-WEN1
End plate (D side)
EX600-ED4
End plate (U side)
EX600-EU1
1
3
0
2
3
5
7
10
2
4
8
D side
U side
Wireless unit
(Remote module)
EX600-WSV1
End plate (D side)
EX600-ED4
End plate (U side)
EX600-EU1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
U sideD side
12345
Valve stations
1
3
0
2
3
5
7
10
2
4
8
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
AB
B
12
A
14
2-position single
SY3100-5U1 (3 sets)
2-position double
SY3200-5U1 (2 sets)
Wireless unit
(Remote module)
EX600-WSV1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
End plate (D side)
EX600-ED4
Ordering Example of the Base Module
Ordering Example of the Remote Module
Base module: Without valve manifold and input/output unit
Remote module: Without valve manifold and with input/output unit
Manifold with base module: With input/output unit
Manifold with remote module: With input/output unit
SS5Y3-10S6WE72-05B-C6
(Type 10 5-station manifold base, Base EtherNet/IPcompatible)
Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations
SY3100-5U1
·················
3 sets (2-position single part no.)
SY3200-5U1
·················
2 sets (2-position double part no.)
EX600-DXPD
················
1 set I/O unit part no. (Stations 1)
EX600-DYPB
·················
1 set I/O unit part no. (Stations 2)
EX600-ED4
·······························
1 set
EX600-WEN1
·····························
1 set
EX600-EU1
·······························
1 set
EX600-ED4
·······························
1 set
EX600-DXPD
·····························
1 set
EX600-DYPB
·····························
1 set
EX600-WSV1
·····························
1 set
EX600-EU1
·······························
1 set
SS5Y3-10S6WS72-05B-C6
(Type 10 5-station manifold base, remote)
Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations
SY3100-5U1
·················
3 sets (2-position single part no.)
SY3200-5U1
·················
2 sets (2-position double part no.)
EX600-DXPD
················
1 set I/O unit part no. (Stations 1)
EX600-DYPB
·················
1 set I/O unit part no. (Stations 2)
The asterisk denotes the symbol for the assembly.
Prefi x it to the part numbers of the valve, etc.
The asterisk denotes the symbol for the assembly.
Prefi x it to the part numbers of the valve, etc.
·
For details, refer to the catalogue of each valve series.
·
Products should be ordered separately and
assembled by the customer.
·
Products should be ordered separately and
assembled by the customer.
·
For details, refer to the catalogue of each valve series.

Related product manuals