Loading...
- 105 -
LEPY Basic parameter default
LEPY Return to origin parameter default
Model
LEPY6
LEPY10
Lead [mm]
4
8
5
10
Basic parameter default
Controller ID
1
1
IO pattern
1
1
Acceleration /
Deceleration pattern
1
1
S-motion ratio
0
0
Storoke (+)
1000.00
1000.00
Storoke (-)
-1000.00
-1000.00
Maximum speed
150
300
200
350
Maximum acceleration /
deceleration
3000
3000
Default In position
0.50
0.50
ORIG offset
0.00
0.00
Max force
100
100
Para protect
1
1
Enable SW
2
2
Unit name
Part no. of each product
W-AREA1
0.00
0.00
W-AREA2
0.00
0.00
ORG Correct
0.00
0.00
Sensor type
1
1
Option set1
1
1
Undefined parameter11
1
1
Undefined parameter12
1
1
Model
LEPY6
LEPY10
Return to origin parameter default
ORIG direction
2
2
ORIG mode
1
1
ORIG limit
150
150
ORIG time
100
100
ORIG speed
LEP□□J:20
LEP□□K:10
LEP□□J:20
LEP□□K:10
ORIG ACC / DEC
3000
3000
Creep speed
20
20
ORIG sensor
0
0
ORIG SW Dir
0
0
Undefined parameter21