- 104 -
Appendix 1.6 LEP series setting value
LEPY Step data default
When the stroke is 25mm, the initial value becomes “250”.
Model
LEPY6
LEPY10
Lead [mm]
4
8
5
10
Step data default
No.
0
0
Movement MOD
ABS
ABS
Speed
150
300
200
350
Position
0.00
0.00
Acceleration
3000
3000
Deceleration
3000
3000
Pushing force
100
100
100
100
Trigger LV
100
100
100
100
Pushing speed
10
20
10
20
Moving force
150
150
Area1
0.00
0.00
Area2
0.00
0.00
In position
0.50
0.50