- 43 -
Undefined
parameter
No.11
1 to 4096
Define the ratio of electronic gear of pulse signal input.
Undefined parameter 11
: "Electronic gear (numerator)"(Default: 1)
Undefined parameter 12
: "Electronic gear (denominator)"(Default: 1)
This product controls LE series motor (800 pulse per
rotation).
Please refer to the electric actuator manual for the
appropriate range of the movement due to the rotation of
the motor.
<Example>
(1) "Electronic gear (numerator): 1",
"Electronic gear (denominator): 1"
→ Motor makes one turn when 800 pulses are input.
(2) "Electronic gear (numerator): 2",
"Electronic gear (denominator): 2"
→ Motor makes one turn when 1600 pulses are input.
(3) "Electronic gear (numerator): 2",
"Electronic gear (denominator): 1"
→ Motor makes one turn when 400 pulses are input.
"Electronic gear (numerator): 1", "Electronic gear
(denominator): 1" is recommended. If other values are
selected, the vibration or noise of the electric actuator can
result.
If set “0”, the set value is recognized as “1”.
If set more than 4097”, the set value is recognized as 4096”.
X