‐CW420/430
19
6.7 Autostartfunction
Modifytheparameter(ON/OFF)bypressing .
Setat“on”tostartthecyclewhenthedoorisclosed.
Setat“off”forcyclestartafterconfirmationwiththestartbutton
6.8 Regenerationfrequencysetup(modelswithsoftener)
(Defaultvalue:H03;modifytheparametertosuitthemainswaterhardness.
At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with
regeneratingsaltwhennecessary.
Modifythe
valueofthe
parameterby
pressing .
Hardness
(°dGerman
degrees)
Hardness(°f
French
degrees)
Setting
level
Regeneratio
noff
Regeneration
off
H00
8.5 15 H01
11 20 H02
17 30 H03
22.5 40 H04
28 50 H05
Regenerationcycleduration:12minutes 33.5 60 H06
With values over 60°dF an external water treatment device must be used and the regeneration
frequencymustbesetonH00.
6.9 tStP(minimumrinsingtemperature)function
Modifytheparameter(ON/OFF)bypressing .
Set at “on” for minimum rinsing temperature as set; set at “off” for rinsing regardless of boiler
temperature.
If the parameter is set as “off” and hot intake water is not used, the minimum rinsing temperature
mightbeafewdegreeslowerthanthesetting.