ITYS
1-10 kVA
安装及操作手册
CN
Installations- und bedienungsanleitung
DE
Manual de instalación y uso
ES
Manuel d’installation et d’utilisation
FR
Installation and operating manual
GB
Manuale di installazione e uso
IT
Installatie– en bedieningshandleiding
NL
Dokumentacja Techniczno-Ruchowa
PL
Manual de instalação e funcionamento
PT
Manual de instalare şi utilizare
RO
Руководство по установке и эксплуатации
RU
Navodila za priključitev in uporabo
SI
Kurulum ve kullanım kılavuzu
TR

Other manuals for socomec ITYS

Questions and Answers

  • S
    Stephen JohnsonSep 3, 2025
    What to do if socomec UPS shows output short circuit?
    • R
      Richard HillSep 3, 2025
      If your socomec UPS indicates an output short circuit, check the UPS output and the connected loads. Ensure the short circuit is removed before turning the UPS back on.
  • C
    Christina FarmerSep 2, 2025
    What does input bad wiring mean on socomec ITYS?
    • K
      Katie GoodmanSep 2, 2025
      If your socomec UPS displays 'Input bad wiring,' it means the phase and neutral conductors at the input of the UPS system are reversed. Site Fault detection is disabled by default but can be enabled/disabled from the LCD settings menu. Reconnect all input wires correctly.
  • M
    Michelle ReyesSep 1, 2025
    Why socomec ITYS displays no battery?
    • A
      Adam OconnellSep 2, 2025
      If your socomec UPS displays a 'No Battery' message, it indicates that the batteries are disconnected. Check that all batteries are properly connected.
  • B
    Bill MezaAug 31, 2025
    What causes emergency power off on socomec ITYS UPS?
    • N
      Nicholas ArroyoAug 31, 2025
      Emergency power off on your socomec UPS is activated when the RPO (Remote Power Off) is active. Check the RPO connector status to resolve this.
  • J
    Jeffrey SalazarAug 30, 2025
    What does battery low mean on socomec UPS?
    • J
      Jeffrey LeonardAug 31, 2025
      When your socomec UPS indicates 'Battery Low', it means the UPS is operating in Battery mode and the battery is running low. Note that the time to shutdown is approximate and may vary significantly.
  • O
    ohenryAug 29, 2025
    What to do for over-temperature fault on socomec ITYS UPS?
    • R
      rogersmorganAug 30, 2025
      If your socomec UPS indicates an over-temperature fault, the internal temperature is too high, causing the UPS to go to bypass or stop. Check the UPS ventilation and the ambient temperature to ensure they are within acceptable limits.
  • V
    Veronica GutierrezAug 28, 2025
    Why socomec UPS does not start?
    • H
      hahncynthiaAug 29, 2025
      If your socomec UPS doesn't start, the input source may not be connected correctly, or the Remote Power Off (RPO) switch might be active, or the RPO connector may be missing. Check the input connections and, if the UPS Status menu displays the 'Remote Power Off' notice, deactivate the RPO input.
  • J
    Joseph CoxAug 28, 2025
    What to do if socomec UPS shows battery fault?
    • K
      Kurt BookerAug 28, 2025
      If your socomec UPS displays a battery fault, it means the battery test has failed. This could be due to bad or disconnected batteries, or the battery minimum voltage being reached in Optimize Battery Management cycling mode. Check that all batteries are properly connected. You can start a new battery test. If the condition persists, contact your service representative.
  • M
    Michelle MooreAug 27, 2025
    Why socomec ITYS does not provide expected backup time?
    • A
      Ashley LeeAug 27, 2025
      If your socomec UPS isn't providing the expected backup time, the batteries may need charging or servicing. Connect the UPS to mains power for 48 hours to allow the batteries to charge. If the problem persists, contact your service representative.
  • A
    Ashley PearsonAug 26, 2025
    What causes over-temperature warning on socomec ITYS?
    • M
      Michael HenryAug 27, 2025
      An over-temperature warning on your socomec UPS indicates that the internal temperature is too high. To resolve this, clear any obstructions from the vents, remove any nearby heat sources, and ensure that airflow around the UPS is not restricted. The UPS will continue to operate in its current state while the warning is active.

Summary

Warranty Information

Return-to-Base Warranty

Details the warranty terms for repairs and replacements, including return shipping responsibilities.

Warranty Claims and Procedures

Outlines the steps required to claim service under warranty, including required documentation.

Battery and Software Warranty

Specifies warranty coverage for batteries and software products, including limitations.

Safety Standards

Important Safety Precautions

Crucial safety advice for operating the UPS, including electrical hazards and battery handling.

ITYS 1-3 kVA Specific Safety

Safety measures and installation restrictions applicable to 1-3 kVA models.

ITYS 6-10 kVA Specific Safety

Safety measures and installation restrictions applicable to 6-10 kVA models.

Label Symbols and Warnings

Explains the meaning of warning symbols and labels found on the UPS unit.

Installation Requirements

Environmental Installation Conditions

Specifies optimal ambient temperature, humidity, and ventilation for UPS installation.

Installation Guidelines

Provides instructions on unit placement, clearance, and connections for installation.

Electrical Requirements

Input Specifications and Leakage Current

Details required input protection, leakage current limits, and cable sizing.

Rear View and Connections

Rear Panel Layout (ITYS 1 k & 2 k)

Illustrates the rear panel ports and connectors for ITYS 1 and 2 kVA models.

Rear Panel Layout (ITYS 3 k)

Illustrates the rear panel ports and connectors for the ITYS 3 kVA model.

Battery Extension Connection

Safety Warnings for Battery Extension

Critical safety precautions to observe before connecting external battery modules.

Connection Procedure

Step-by-step instructions for correctly connecting the battery extension cable.

Mimic Panel Overview

Front Panel Display and Controls

Explains the visual indicators, status displays, and control buttons on the UPS front panel.

Operating Modes

Operational States Description

Describes the different operating modes like Normal, Battery, Eco, and Converter modes.

Battery Recharging Procedure

Instructions on how to charge the internal UPS batteries for optimal performance.

Powering the UPS On and Off

Step-by-step guides for safely powering the UPS unit on and off.

Battery Test Functionality

Explains how to initiate and perform a battery health test.

Setting Menu Configuration

Details how to navigate and configure UPS settings through the menu interface.

Warning Signals and Alarms

Alarm Indication and Codes (ITYS 1-3 kVA)

Lists and explains visual and audible alarms, fault codes, and warnings displayed by the unit.

Communication Interfaces

USB Interface Connection

How to connect the UPS to a computer using the USB interface for monitoring.

Optional Network Communication

Information on using optional Web/SNMP cards for remote network management.

RS232 Serial Communication

Details on establishing serial communication via the RS232 port for UPS control.

Troubleshooting Common Issues

Basic Operation Problems

Addresses common operational issues like UPS on battery mode or short backup times.

Display and Alarm Indicator Faults

Troubleshooting issues related to the mimic panel display, alarms, and audible warnings.

Component and Environmental Faults

Diagnosing problems related to fans, temperature, voltage, and internal component failures.

System Errors and Configuration Problems

Addresses common system errors like EEPROM, EPO, bypass, softstart, and battery connection issues.

Performance and Environmental Issues

Diagnoses problems related to battery levels, overload, fan, charger, and temperature issues.

Overload and Short Circuit Faults

Focuses on troubleshooting overload conditions, short circuits, and critical system faults.

Power Supply and Indicator Status

Covers issues related to power indication, bypass LEDs, battery LEDs, and backup time indicators.

Technical Specifications (1-3 kVA)

Detailed Specifications for 1-3 kVA Models

Comprehensive technical data including electrical, environmental, and mechanical characteristics.

Safety Standards (6-10 kVA)

Electrical Requirements for 6-10 kVA

Specific electrical safety requirements and parameters for the 6-10 kVA UPS models.

Rear View (6-10 kVA)

Rear Panel Layout (ITYS 6 k)

Illustrates the rear panel ports and connectors for the ITYS 6 kVA unit.

Rear Panel Layout (ITYS 10 k)

Illustrates the rear panel ports and connectors for the ITYS 10 kVA unit.

Connections and Wiring

Electrical Connection Diagrams

Visual guides showing how to make the necessary electrical connections for the UPS.

Battery Extension Connection (Models 6-10 kVA)

Safety Warnings for Battery Extension

Critical safety precautions to observe before connecting external battery modules.

Connection Procedure

Step-by-step instructions for correctly connecting the battery extension cable.

Mimic Panel Display

Mimic Panel Indicators and Alarms

Explains the status indicators, alarms, and control buttons on the UPS front panel.

Operating Modes and Controls

Switching the UPS On

Procedures for safely powering the UPS unit on.

Switching the UPS Off

Procedures for safely powering the UPS unit off.

Detailed Operating Mode Descriptions

Explains the different operational modes like Line, Battery, Eco, Converter, and Bypass.

Setting Menu Navigation

Presents the hierarchical structure of the UPS's setting menu for configuration.

Manual Bypass Operation

Describes how to activate and use the manual bypass feature for maintenance purposes.

Transition from Bypass to Normal Operation

Explains the procedure for safely returning the UPS from manual bypass to normal operating mode.

Visual and Audible Warning Signals

Mimic Panel Indicators and Alarms

Explains the meaning of indicators, alarms, and their conditions displayed on the mimic panel.

Communication Interfaces

USB Interface Connection

How to connect the UPS to a computer using the USB interface for monitoring.

Optional Network Communication

Information on using optional Web/SNMP cards for remote network management.

RS232 Serial Communication

Details on establishing serial communication via the RS232 port for UPS control.

Dry Contact Interface

Pin assignments and descriptions for the dry contact interface for external signaling.

Technical Specifications (6-10 kVA)

Detailed Specifications for 6-10 kVA Models

Comprehensive technical data including electrical, environmental, and mechanical characteristics for higher capacity models.

socomec ITYS Specifications

General IconGeneral
Frequency50/60 Hz
Input Voltage230 VAC
Output Voltage230 VAC
Form FactorTower
Power Factor0.9
Operating Temperature0 to +40 °C
Communication InterfaceUSB, RS232
Protectionshort circuit protection
TopologyLine Interactive
Battery TypeSealed Lead-Acid (SLA)
Noise Level< 45 dBA (depending on model)