January 26
th
, 2022 3
Warning Symbols
This symbol indicates information that, if ignored, could result in minor injury or
damage to the equipment.
This symbol indicates information that, if ignored, could result in serious injury,
damage to the equipment, or death.
This symbol indicates information that is important but not hazard-related.
Warnings
Read this entire document before installing or using the Sol-Ark 5K inverter. Failure to follow any of
the instructions or warnings in this document can result in electrical shock, serious injury, or death.
Damage to the 5K inverter is also possible, potentially rendering it inoperable.
High Life Risk Due to Fire or Electrocution ONLY qualified persons should install the Sol-Ark 5K
inverter.
The system must have Ground connections and Neutral connections. Ground MUST be bonded to
Neutral ONLY ONCE in the circuit.
Solar PV+/PV- are UNGROUNDED. Note, you may ground PV Racking/Mounts, but doing so directly
to the Sol-Ark will likely result in damage in the case of a direct lightning strike to the PV array.
DO NOT connect the grid to the Load Output Breaker.
DO NOT reverse the polarity of batteries. Damage WILL occur.
DO NOT exceed more than 500Voc on any MPPT on the Sol-Ark.
DO NOT use impact drivers to tighten any fasteners on the Sol-Ark.
MUST use Strain Reliefs ON ALL wires entering/exiting the Sol-Ark 5K user area.
MUST use conduit (or double insulated wire) for AC Wires entering/exiting Sol-Ark 5K user area.
ALL terminals/breakers including battery, MPPT, and AC breaker inputs should only have one
conductor connecting to them.