How to unfreeze the color touchscreen on my sol-ark 5K Inverter?
- VVictoria MooreSep 23, 2025
To unfreeze the color touchscreen on your Sol-Ark Inverter, press and hold the escape button for 7-10 seconds.
How to unfreeze the color touchscreen on my sol-ark 5K Inverter?
To unfreeze the color touchscreen on your Sol-Ark Inverter, press and hold the escape button for 7-10 seconds.
What to do if my sol-ark 5K system is beeping?
If your Sol-Ark Inverter system is beeping, check the system alarms menu to identify the triggered alarm. Many alarms will self-reset. Alternatively, if you are not using a battery, ensure you've selected 'no battery' and disabled 'activate batt' in the Battery menu.
What to do if the alarm light is on in my sol-ark 5K?
If the Alarm Light is illuminated on your Sol-Ark Inverter, check the system alarms menu to determine which alarm has been triggered.
Why does my sol-ark 5K system connect to the grid and quickly disconnect?
If your Sol-Ark Inverter system connects to the grid and then quickly disconnects, verify that your Neutral wire is properly connected using a DMM (it should read 0Vac referenced to GND). Also, confirm that your Frequency is set to 60Hz and the inverter is receiving 120V on L1 & L2 to Neutral. If overloading, ensure the 120/240V grid input and load output wires are not swapped. For 120/208V systems, the L1 and L2 lines are phase-specific, so you may need to swap Grid L1 and L2 for 208V applications.
How to troubleshoot sol-ark 5K panels not producing power?
If the panels connected to your Sol-Ark Inverter are not producing power, check that all solar panel connections are wired properly and that the PV disconnect is turned on. Also, ensure that the PV input voltage is not greater than 425V. If the system indicates PV=0V, verify the PV polarity.
Why is my sol-ark Inverter generator setup reading 0Hz?
If the Generator setup is reading 0Hz on your Sol-Ark Inverter, select “General Standard” instead of UL1741. Then widen the voltage range to 53Hz-65Hz.
What happens if batteries were connected backwards to my sol-ark 5K Inverter?
If batteries were connected backwards to your Sol-Ark Inverter, the battery breaker will trip, which can cause damage!
Why is the batt % meter not reaching 100% on my sol-ark 5K Inverter?
If The Batt % meter is not reaching 100% on your Sol-Ark Inverter, the system needs to go through a small discharge/charge cycle to first calibrate the battery.
Why is auto gen-start not working on my sol-ark 5K Inverter?
If the Auto Gen-Start feature is not working on your Sol-Ark Inverter, first ensure that your generator is compatible with Auto Start. Then, verify that the Auto Gen Start wire is connected properly to both the Sol-Ark 5K and the generator.
Why are my sol-ark Inverter panels not producing much power?
If your Sol-Ark Inverter panels are not producing much power, ensure the PV wire strip length is 5/8”. Your batteries may be charged, so you can test Grid Sell to verify.
Lists all included components for the system, such as sensors, cables, and mounting hardware.
Explains the 4-stage MPPT battery charging algorithm for efficient and safe charging.
Details on using the Gen input for high power loads like water heaters or pumps.
Further options like Grid Sell, Time of Use, Sell Control, and grid connection parameters.
Explains the status lights on the inverter for DC, AC, Normal, and Alarm conditions.
Choosing operational modes like Grid Sell, Limited To Home, and Off-Grid.
Covers graphical views, system setup menus, alarms, and detailed voltage views.
Addresses common problems with LCD, panels, generator, battery, and grid connections.
Lists specific fault codes, their common causes, and recommended remedies.
Lists compatible rapid shutdown devices and module level options.
Details communication protocols, pinouts, and settings for MODBUS and CANBUS.
| Max DC Input Voltage | 500V |
|---|---|
| Frequency | 60 Hz |
| Continuous Power Output | 5000W |
| Battery Voltage | 48V |
| AC Output Voltage | 120V/240V |
| MPPT Range | 120V-450V |
| Max PV Input | 6500W |
| Certifications | UL1741, FCC Part 15 Class B |