Step 2: Remove the DC and AC conductors.
1. Cut off the zip ties from the ferrite ring (choke) with the wire cutters.
2. Remove the four screws with the #1 Philips screwdriver to detach DC conductors from the
power board.
NOTE
Positive conductors are attached to the two terminals to the left.
Negative conductors are attached to the two terminals on the right.
3. Unwind the DC cables through the ferrite ring (choke) and save the ring for the new inverter.
4. Remove the four screws that attach the AC conductors to the power board with the #1
Phillips screwdriver. Save the screws to reattach the new inverter top.
Step 3: Remove the communications connector.
1. Remove the communications connector on the bottom of the inverter with the needle nose
pliers.
2. Make sure to grasp the middle section of the connectors to release the metal clip holding it
in place.
NOTE
When removing the connectors be careful not to damage the plugs or the cables.
3. Guide the communications connectors to the top part of the inverter.