Installation Guide
Inline Energy Meter with
SolarEdge Energy Net
Communications
For Europeand Australia
Version 1.0

Questions and Answers

  • M
    Michael McintoshJul 28, 2025
    What to do if my SolarEdge Inverter has a power failure?
    • L
      lindseysmithJul 28, 2025
      If your SolarEdge Inverter is experiencing a power failure, verify that the main circuit breaker is in the ON position. Also, ensure that the phase AC line is connected to the L3 connector and the neutral AC line is connected to the N connector on the meter.
  • D
    Dwayne MortonAug 8, 2025
    How to troubleshoot communications failure on SolarEdge Inverter?
    • T
      tiffany11Aug 8, 2025
      If your SolarEdge Inverter is failing to communicate, several factors could be at play. Here's what to check: * If using Energy Net, confirm that an Energy Net module and an external antenna are properly installed in the inverter. * For inline meters in metal cabinets, or if you suspect range issues, an external antenna for the meter may be needed. * If the meter and inverter are connected via RS485 wiring, ensure the wiring follows the correct guidelines. * Verify the meter is configured correctly. * Inspect the conduit for water penetration and repair any leaks. * Use outdoor rated components. * Measure the voltage on the meter's AC wiring with a voltmeter, ensuring the L1 – L2 – L3 line to line voltage is 208-240 Vac.
  • C
    Charles FrenchAug 18, 2025
    Why is the energy value not advancing on my SolarEdge Inline Energy Meter?
    • C
      Casey StewartAug 18, 2025
      If the energy value on your SolarEdge Inverter is not advancing, ensure that the correct meter function is selected and the AC Grid Connection is configured correctly. Check the Energy value in the Meters section of the Status page. Also, make sure that there are no loose connections at the inverter connectors and at the meter, specifically the AC wiring on the meter's AC wiring connector. Inspect the entire conduit run for possible points of water penetration, and fix leaks. Ensure that proper outdoor rated components are used.

Summary

Handling and Safety Instructions

Safety Symbols Information

Explains the meaning of safety symbols (Warning, Caution, Note) used to highlight hazards and important information.

Chapter 1: Inline Energy Meter Overview

Chapter 2: Meter Installation

Installation Guidelines

Covers AC/RS485 wiring specifications and general safety guidelines for meter installation.

Installing and Connecting the Inline Meter

Step-by-step guide for mounting the meter on a DIN rail and detaching it.

Chapter 3: Device Configuration

Device Configuration Steps

Details configuration of the meter function, connection type, and other settings via SetApp.

Appendix A: Troubleshooting

Troubleshooting Meter Connection

Diagnosing and resolving power failures and communication errors using SetApp.