Version 1.0, October 2024
Replace Top of Home Hub Inverter North America
6
4. Guide communication cables through the left opening in the new inverter.
5. Reattach the metal clips to the inverter mounting pins on top of DCD unit to connect the top
to the bottom of the inverter.
Step 2: Reconnect the DC and AC conductors.
1. Connect the AC wires to the AC terminals on the power board of the new inverter with a
Phillips #1 screwdriver and tighten to 1.2Nm or 10.62lbf-in. Install the EMI filter between the
neutral and ground terminals as shown in the picture below.
WARNING!
Wire the AC cables according to the order in the picture below. Failure to do so can result
in injury or damage.
2. Feed the DC conductors through the Ferrite ring (choke) twice.
3. Attach the DC conductors to the new power board and tighten to 1.2Nm or 10.62in-lbs.