Backup
interface
G A B
+ 12 -
G A B 12- 12+
E
Chaining Multiple Inverters
LED Indications
Red: fault
Green: power production,
Blinking Green: Grid connection ok
Blue: communication ok
For more indications refer to:
https://www.solaredge.com/leds
F
Commissioning the Inverter
SetApp
2
4
ON
P 1 0
P (Hold for 5 seconds and release)
3
1
1
7
5
9
3
4
10
6
8
2
Run SetApp and
follow the instructions
on the screen
4 N*m
I J
For remote status, fault indications, and system
performance, refer to Remote Monitoring at:
https://www.solaredge.com/products/pv-monitoring#/
RS485-2
Communication Board
SW1 SW2
1.5 N*m
CAT5e/6 cable
G
Meter Connection (Connect Meter ONLY if:
1. BUI not installed - 2. Backup configuration is set to "partial home backup-
3. Meter is installed to support third-party production inverters)
Meter
G A B
1.5 N*m
CAT5e/6 cable
Battery Connection
D
Battery
communication
(CAN)
1
SW2
CAT5e/6 cable
Leader (first) Follower (last)
C
SolarEdge Home Network Connection
1.1 N*m
Inline Meter
G A B
12- 12+
1.5 N*m
LAN Connection
Ethernet Cable
Router
CAT5e/6 cable
H
LAN cable
NOTE: In Leader-Follower
configuration, LAN MUST
connect to Leader
Follower
Backup Interface (BUI) and Manual
Shutdown (MSD) Switch Connection
SW2
SW2
2
4
8 N*m
Max cables length 5 m
Communication Cable
Ground Cable
IMPORTANT! The connection to units and accessories shown here is for reference only. For detailed information, refer to the specific product guide.
Smart
Energy Hot
Water
2.2 N*m
+
-
3
Click!
5
Manual
Shutdown
(MSD) Switch
(Not included)
N.C N.C L1 L2 L3 L4 G V
V
L1
N.C
B A G
B A GB A GB A G
Use a Normally Closed (N.C) switch that
latches in an open position when pressed, and
when pressed again, returns to the closed
position. Scan QR for MSD application note.