Indication
ON/
OFF/ P
Switch
Position
LEDColor
Comment
Red Green Blue
Power
optimizers not
paired
ON (1)
OFF Blinking
S_OK: ON
No S_OK:
OFF
S_OK: ON
communication with
the monitoring
platform is
established.
Pairing Blinking Blinking Blinking
Wake-up/ Grid
Monitoring
OFF Blinking Blinking
System
Producing
OFF ON
S_OK: ON
No S_OK:
OFF
For detailed
percentage of
production, refer to
the following table.
Night mode
(no
production)
OFF Flickering
S_OK: ON
No S_OK:
OFF
Inverter is OFF
(Safe DC)
OFF (0)
OFF Blinking
S_OK: ON
No S_OK:
OFF
Inverter is OFF
(DC not safe)
Blinking Blinking
S_OK: ON
No S_OK:
OFF
Inverter
configuration
or reboot
ON / P ON ON ON
Inverter
firmware
upgrade
ON / P Alternating Alternating Alternating
The upgrade process
can take up to 5
minutes
Error Any ON
ON/ OFF/
Blinking/
Flickering
ON/ OFF /
Blinking
Refer to
Errors and
Troubleshooting
on
page 60
The following table describes production percentage of AC information by LED color
and ON/OFF/P switch position.
Three Phase Inverter with SetApp Configuration PN: SEXXK-XXXXIXXXX
25 Inverter and DC Safety Unit Interfaces