Malfunction Possible Cause and Corrective Action
String voltage is higher than number
of optimizers
WARNING!
If the measured voltage is too
high, the installation may not
have a safe low voltage.
PROCEED WITH CARE! A
deviation of ±1% per string is
reasonable.
Extra power optimizer(s) connected in the string
(not applicable to smart modules).
Check if an extra power optimizer is connected in
the string. If not – proceed to next solution.
A module is connected directly to the string,
without a power optimizer (not applicable to
smart modules).
Verify that only power optimizers are connected
in the string and that no module outputs are
connected without a power optimizer. If the
problem persists, proceed to the next step.
Power optimizer(s) malfunction.
1. Disconnect the wires connecting the power
optimizers in the string.
2. Measure the output voltage of each power
optimizer to locate the power optimizer that
does not output 1V safety voltage. If a
malfunctioning power optimizeris located,
check its connections, polarity, module, and
voltage.
3. Contact SolarEdge Support. Do not continue
before finding the problem and replacing the
malfunctioning power optimizer. If a
malfunction cannot be bypassed or resolved,
skip the malfunctioning power optimizer,
thus connecting a shorter string.
StorEdge Three Phase Inverter MAN-01-00648-1.3
63 Power Optimizer Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge StorEdge SE5K-RWS and is the answer not in the manual?

SolarEdge StorEdge SE5K-RWS Specifications

General IconGeneral
BrandSolarEdge
ModelStorEdge SE5K-RWS
CategoryInverter
LanguageEnglish

Related product manuals