(caused by capacities of the PV modules to ground) and leakage currents (caused by
touching a pole of the PV generator). If the inverter detects an excess in the permissible
leakage or stray currents, it will disconnect from the grid.
Functions for current and power limitation
The inverters of the P series limit the DC feed-in current, the output power and the AC
output current.
Temperature limitation
At ambient temperatures of more than 45 °C the equipment temperature may reach more
than 80 °C. In such cases, the maximum in-feed power is temporarily reduced. When the
equipment temperature rises to over 85 °C, the inverter disconnects from the grid.
3.4 Dimensions
104.5
480 189
[mm]
256.5
361