119
Troubleshooting and Maintenance
Error Code Fault Descriptions and Diagnosis
IE 106 Bat Temp Low
Battery temperature low
Check the battery installation environment to
ensure good heat dissipation.
Check if the battery heat function is enabled on the
LCD screen of inverter and the heating time period
is correctly set.
Or contact SolaX for help if it can not return to
normal.
IE 107 Bat Temp High
Battery temperature high
Check the battery installation environment to
ensure good heat dissipation.
Or contact SolaX for help if it can not return to
normal.
IE 109 Meter Fault
Meter Fault
Check if the meter is working properly
Or contact SolaX for help if it can not return to
normal.
IE 110 BypassRelayFlt
Bypass relay fault
Press the ESC key to restart the inverter.
Or contact SolaX for help if it can not return to
normal.
IE 111 ARMParaComFIt
ARM Parameter Communication fault
Check that the communication cables of inverters
are well connected and the baud rate of COMM
setting of inverters are the same.
Or contact SolaX for help if it can not return to
normal.
IE 112 FAN1 Fault
FAN1 Fault
Check if the foreign objects stuck in the fan.
Or contact SolaX for help.
IE113 FAN2 Fault
FAN2 Fault
Check if the foreign objects stuck in the fan.
Or contact SolaX for help.
IE108 FAN3 Fault
FAN3 Fault
Check if the foreign objects stuck in the fan.
Or contact SolaX for help.
BE 01
BMS1_Exter_Err
Battery Error - External Communication Fault
Please contact SolaX for help.
BMS2_Exter_Err
BE 02
BMS1_InterErr
Battery Error - Internal Communication Fault
Please contact SolaX for help.
BMS2_InterErr