EasyManua.ls Logo

Solax X1 Series - Technical Data and System Standards; DC Input and AC Output Specifications; System Data, Protection, and Standards

Solax X1 Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
15
Technical DataTechnical Data
4. Technical Data
4.1 DC Input
4.2 AC Output
1200
450
50
360
40-450
2200
450
50
360
40-450
3000
450
50
360
40-450
4000
450
50
360
40-450
1/1
16
22
X1-MINI
-0.6K-G4
Model
I PV array Short Circuit
SC
Current [d.c.A]
Max. PV array input power [Wp]
Max. PV voltage [d.c.V]
Startup voltage [d.c.V]
Nominal input voltage [d.c.V]
MPPT voltage range [d.c.V]
No. of MPP trackers/Strings
per MPP tracker
Max. PV current [d.c.A]
5000
550
50
360
40-550
6000
550
50
360
40-550
700
3.1
1100
4.8
1500
6.5
2000
8.7
Rated output apparent power [VA]
Nominal AC output current [a.c.A]
Max. output apparent
power [VA]
Max. output continuous current
[a.c.A]
Nominal AC voltage [a.c.V]/
Grid range
Nominal grid frequency [Hz]
220/230/240; 90-290
50/60; ±5
0.8leading-0.8lagging
<3
Displacement power factor
ITHDi (rated power) [%]
Model
2500
10.9
3300
14.4
3000
13.1
1400
450
50
360
40-450
600
6600
550
50
360
40-550
2.6
600
3
770
3.5
1210
5.5
1650
7.5
2200
10
2750
12.5
3300
15
3300
15
X1-MINI
-0.7K-G4
X1-MINI
-1.1K-G4
X1-MINI
-1.5K-G4
X1-MINI
-2.0K-G4
X1-MINI
-2.5K-G4
X1-MINI
-3.0K-G4
X1-MINI
-3.3K-G4
X1-MINI
-0.6K-G4
X1-MINI
-0.7K-G4
X1-MINI
-1.1K-G4
X1-MINI
-1.5K-G4
X1-MINI
-2.0K-G4
X1-MINI
-2.5K-G4
X1-MINI
-3.0K-G4
X1-MINI
-3.3K-G4
4.3 System Data, Protection and Standard
98
96
98
97
98
97
98
97
Max. efficiency [%]
Euro. efficiency [%]
Standby consumption
[W] @Night
Over/under voltage protection YES
DC isolation protection YES
Monitoring ground fault protection YES
Grid monitoring YES
DC injection monitoring YES
Back feed current monitoring YES
Residual current detection YES
Anti-islanding protection YES
Over temperature protection YES
SPD (PV/AC) Type II (Optional)
98
97
98
97
98
96
98
97
Ingress protection
Protective class
Overvoltage category
Operating ambient temperature
range []
Max. operation altitude [m]
Humidity [%]
Typical noise emission [dB]
Storage temperature []
Dimensions(W×H×D) [mm]
Weight [kg]
Cooling concept
<1
I
II (DC),III (AC)
-25-60
<4000
0-100
25
-30-70
290x206x120
5.2
5.5
5.2 5.2 5.2 5.2
5.5
5.5
Nature cooling
AFCI Optional
Safety EN/IEC62109-1/2
Grid monotoring
X1-MINI
-0.6K-G4
X1-MINI
-0.7K-G4
X1-MINI
-1.1K-G4
X1-MINI
-1.5K-G4
X1-MINI
-2.0K-G4
X1-MINI
-2.5K-G4
X1-MINI
-3.0K-G4
X1-MINI
-3.3K-G4
IEC61727, EN50549, G98, AS 4777.2, VDE4105, CEI 0-21, VFR
Communication interfaces
RS485/DRM/USB/Heat Pump, Optional: CT/Meter;
Optional monitoring dongle
Pocket WiFi/LAN/4G
Max. inverter backfeed current
to the array [d.c.A]
0
Current (inrush) [a.c.A]
50
58 (15 ms)
35
Maximum output fault current [a.c.A]
Maximum output overcurrent
protection [a.c.A]
Active anti-islanding method
Frequency shift
Inverter typology
Non-isolated