4
Copyright
©
2018 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
2.2.1. Programming the first 1W Somfy io control point for an LED light
1) Switch on the power supply.
2) Press the Up and Down buttons simultaneously on the 1W io
control point and follow procedure 2.2.1.1. or 2.2.1.2. according to
the reaction of the LED light(s).
2.2.1.1. An LED light comes on then goes out
Case 1: It is for this LED light that the control point must be programmed
• Briefly press the PROG button on this io control point.
The LED light comes on then goes out.
The io control point has been programmed for this LED light.
Case 2: It is not for this LED light that the control point must be programmed
• Press the Up and Down again simultaneously
on the 1W io control point and repeat if
necessary until the desired LED comes on then goes out.
If the output selected is not connected to any LED light, nothing
will come on. Select a different output.
• Briefly press the PROG button on this io control point.
The LED light comes on then goes out.
The io control point has been programmed for this LED light.
2.2.1.2. No LED light comes on
Press the Up button.
• If one or more LED lights come on:
The io control point has been programmed for the LED lights
lit.
- Go to section 2.3.
• If no LED light comes on:
check the status of the LED lights and the connection and
try again.
- Go to section 2.3.3.
2.2.2. Activating / deactivating automatic cut-off
Prerequisite: Commissioning has been completed using a 1W io control point.
This function allows an LED light to be switched off automatically aer 3, 6 or 12 hours of operation.
It is possible to configure this period (see 2.2.3.).
ON
2.2.1.1.
2.2.1.2.
PROG.
PROG.
2.3.
2.3.3.