OPERATING MANUAL MIC-2 ver. 1.8
12
- In the case the batteries leak inside the compart-
ment, the meter must be serviced.
- Accumulators must be charged in an external
charger.
5 Cleaning and maintenance
The casing of the meter may be cleaned with a
soft, damp cloth using all-purpose detergents. Do
not use any solvents or cleaning agents which
might scratch the casing (powders, pastes, etc.).
The electronic system of the meter does not
require maintenance.
6 Storage
In the case of storage of the device, the follow-
ing recommendations must be observed:
Clean the meter and all its accessories thor-
oughly,
In the case the meter is to be stored for a pro-
longed period of time, the batteries or accumu-
lators must be removed from the device,
In order to prevent total discharging of accu-
mulators in the case they are stored for a pro-
longed period of time, they must be partially
charged from time to time.
7 Dismantling and utilization
Worn-out electric and electronic equipment
should be gathered selectively, i.e. it must not be
placed with waste of another kind.
Worn-out electronic equipment should be sent
to a collection point in accordance with the law of
worn-out electric and electronic equipment.
Before the equipment is sent to a collection
point, do not dismantle any elements.
Observe the local regulations concerning dis-
posal of packages, worn-out batteries and accumu-
lators.
8 Technical data
8.1 Basic data
„m.v.” refers to the measured value in the in-
trinsic uncertainty specification.
Measurement of AC/DC voltages
Displayed
range
Resolution
Intrinsic uncertainty
0…600V
1V
±(3% m.v. + 2 digits)
Frequency range: 40...200Hz