Sonel MPI-520 Specifications

General IconGeneral
Resolution (Resistance)0.01 Ω
Test voltage (Insulation)250 V, 500 V
DisplayLCD
Power Supply6 x AA batteries
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Current measurement range0.1 mA to 20 A
Capacitance measurement range1 nF to 10 mF
Insulation resistance measurement0.1 MΩ to 2000 MΩ

Summary

2 Menu

2.1 Wireless transmission

Settings for wireless data transfer.

2.2 Settings of measurements

Configure measurement parameters and display.

2.3 Settings of the meter

Adjust display contrast, backlight, and auto-off.

2.4 Language selection

Choose the operating language for the meter.

2.5 Information about manufacturer

Details about the device manufacturer.

1 Safety

3 Measurements

3.1 Measurement of alternating voltage and frequency

Measures network voltage and frequency.

3.4 Measurement of short circuit loop parameters

Measures impedance and fault current in short circuits.

3.5 Measurement of resistance-to-earth

Measures earth resistance using the three-pole method.

3.6 Measurement of RCD parameters

Measures RCD trip current, time, and touch voltage.

3.7 Measurement of insulation resistance

Measures insulation resistance values.

3.8 Low-voltage measurement of resistance

Measures resistance at low voltages.

3.8.3 Calibration of test leads

Calibrates test leads for accurate resistance measurements.

4 Memory of measurement result data

4.1 Recording measurement result data in the memory

Stores measurement results in the meter's memory.

4.2 Viewing memory data

Accesses and displays stored measurement results.

5 Data transmission

5.2 Data transmission with USB joint

Transmitting data via USB connection.

6 Power supply

6.2 Replacement of batteries (accumulators)

Instructions for replacing batteries or accumulators.

7 Cleaning and maintenance

8 Storage

9 Dismantling and utilisation

10 Technical data

10.1 Basic data

General technical specifications and ranges.

12 Positions of the meter's cover

13 Manufacturer

11 Equipment

11.1 Standard Equipment

List of included accessories and test leads.