403
After restarting, the licensed software is now available 
for use.
To cancel the license registration to disable 
functions
Select the software (“Active” displayed in the “Condition” 
field) whose license you want to cancel in the License 
menu (7316.6). Press [Deactivate License] in the License 
Management menu (7316.7), check the message, then 
press [Yes].
Settings Relating to 
Device Management
Setting the Date and Time
1
In the Engineering Setup >System >Maintenance 
menu (7317), set the following parameters.
The specified date and time appear in the “Set” field in 
the status area.
2
Press [Set Date/Time].
3
Check the message, then press [Yes].
Using a Removable Drive
“Removable Drive” refers to general-purpose external 
USB-compatible storage devices connected to the system.
Displaying removable drive information
1
Connect a removable drive to the DEVICE connector 
of the menu panel.
2
In the <USB Storage Device> group of the 
Engineering Setup >System >Maintenance menu 
(7317), press [Refresh].
Initializing a removable drive
Format a commercially available removable drive before 
using it for the first time.
Parameter group [1/2]
No. Parameter Adjustment Setting
1 Hour Hour 0 to 23
2 Min Minute 0 to 59
3 Sec Second 0 to 59
Parameter group [2/2]
No. Parameter Adjustment Setting
1 Month Month 1 to 12
2 Day Day 1 to 31
3 Year Year 2000 to 2037
Note